Search results for "Lesion Complexity"

showing 2 items of 2 documents

Absorb Bioresorbable Scaffold Versus Xience Metallic Stent for Prevention of Restenosis Following Percutaneous Coronary Intervention in Patients at H…

2019

Abstract Background The advent of bioresorbable vascular scaffolds (BVS) was considered as a potential improvement in percutaneous coronary intervention (PCI) after the groundbreaking development of drug eluting stents (DES). However, the clinical performance, long-term safety and efficacy of BVS in complex coronary lesions remain uncertain. COMPARE ABSORB, a multicenter, single blind, prospective randomized trial, aims to compare the clinical outcomes between the Absorb BVS and Xience everolimus-eluting metallic stent (EES) in patients with coronary artery disease and a high risk of restenosis. Design COMPARE ABSORB is designed to enroll 2100 patients at up to 45 European sites. Enrolled p…

MaleBioresorbable scaffoldTime Factorsmedicine.medical_treatmentVascular damage Radboud Institute for Health Sciences [Radboudumc 16]030204 cardiovascular system & hematologyAbsorbCoronary artery diseaseCoronary artery disease0302 clinical medicineRestenosisRisk FactorsAbsorbable ImplantsClinical endpointMulticenter Studies as TopicMedicineSingle-Blind MethodProspective Studies030212 general & internal medicineMyocardial infarctionAngioplasty Balloon CoronaryGeneral MedicineMiddle AgedEuropeTreatment OutcomeMetalsCardiologyFemaleStentsCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyAdolescentProsthesis DesignRisk AssessmentCoronary RestenosisYoung Adult03 medical and health sciencesAll institutes and research themes of the Radboud University Medical CenterInternal medicineHumansAgedbusiness.industryStentPercutaneous coronary interventionCoronary Lesion ComplexityProtective Factorsmedicine.diseaseConventional PCIbusiness
researchProduct

Coronary Stent Strut Fractures: Classification, Prevalence and Clinical Associations

2021

Introduction. The frequency, characteristics and clinical implications of Strut fractures (SFs) remain incompletely understood. Methods and results. A total of 185 (160 patients) newer-generation drug-eluting stents (DES) were imaged. SFs were found in 21 DES (11.4%) and were classified in four patterns: one single stacked strut (41%)

musculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatment030204 cardiovascular system & hematologyArticlecoronary stent03 medical and health sciencesfluids and secretions0302 clinical medicineRestenosisInternal medicineCoronary stentmedicineddc:610cardiovascular diseases030212 general & internal medicineStent thrombosisDevice failureStent restenosisstent thrombosisoptical coherence tomographybusiness.industryRLesion ComplexityGeneral Medicinebioresorbable scaffoldequipment and suppliesmedicine.diseaseThrombosissurgical procedures operativeCardiologyMedicinebusinessBioresorbable scaffoldstent restenosisJournal of Clinical Medicine
researchProduct